1.
Chinese Journal of Infection Control ; (4): 116-120, 2018.
Article in Chinese | WPRIM | ID: wpr-701576

ABSTRACT

Objective To explore the value of class 100 laminar flow ward in the prevention of infection in patients with hematological malignancies(HM) after chemotherapy.Methods Patients with HM and received chemotherapy in the department of hematology in a hospital from March 2016 to February 2017 were surveyed retrospectively,according to patients' wishes,those who were admitted to the class 100 laminar flow ward and received chemotherapy were as trial group,and those who were admitted to the common ward and received chemotherapy were as control group.The incidence of infection,duration of fever,antimicrobial use time,length of hospital stay,and index of infection were compared and analyzed between two groups.Results A total of 267 patients with HM received chemotherapy,74 cases in trial group and 193 in control group.During the chemotherapy period,incidence of infection in trial group was lower than that of control group (47.3% vs 72.0%,P<0.001).Respiratory tract,digestive tract,and urinary tract were main infection sites in both groups.A total of 45 strains of pathogens were isolated from two groups of patients,7 strains were isolated from trial group and 38 from control group.The isolated pathogens were Escherichia coli,Klebsiella pneumoniae,Stenotrophomonas maltophilia,Pseudomonas aeruginosa,and yeast.Duration of fever,antimicrobial use time,and length of hospital stay in trial group were all lower than control group (all P<0.05);serum procalcitonin (PCT) and C-reactive protein (CRP) levels in trial group were both lower than control group(both P<0.01),the time for PCT and CRP to return to normal in trial group were both lower than control group(both P<0.05).Conclusion Patients with MH and receive chemotherapy in class 100 laminar flow ward can reduce the incidence of infection,shorten the length of stay,and reduce the economic burden,it is worthy of further clinical promotion.

2.
Chinese Journal of Infection Control ; (4): 250-253, 2016.
Article in Chinese | WPRIM | ID: wpr-486673

ABSTRACT

Objective To evaluate the effect of class 10000 laminar flow ward on the incidence of healthcare-asso-ciated infection (HAI)in patients with initial occurrence of acute leukemia during induction chemotherapy period. Methods Patients with initial occurrence of acute leukemia admitted to a hematological department of a hospital be-tween October 2013 and June 2014 were investigated retrospectively,patients in class 10000 laminar flow ward was as trial group,in general ward was as control group. All patients received standard induction chemotherapy and the same nursing measures,the incidence of HAI between two groups of patients,and ward air cleanliness were com-pared.Results A total of 79 patients with initial acute leukemia were received (trial group,n= 39;control group, n= 40). The average air cleanliness value in rooms and corridors of laminar flow wards were both significantly dif-ferent with general ward (3.57×106/m3 vs 149.36×106/m3 ,t= 45.80,P<0.001;24.46×106/m3 vs 15854.38 ×106/m3 ,t= 108.70,P<0.001). Incidence of HAI between trial group and control group was significantly differ-ent (23.08% [9/39]vs 45.00% [18/40],χ2= 4.219,P= 0.040). The main infection site in trial group was gastro-intestinal tract (n= 5 ),in control group was lower respiratory tract (n= 8 ). The duration of fever,duration and cost of antimicrobial use in trial group were (6.20±2.10)d,(9.35±2.12)d,and (27113.79±1559.03)yuan re-spectively,in control group were (10.20±2.90)d,(14.15±3.14)d,and (58566.29±2217.54)yuan respectively, difference in duration of fever and cost of antimicrobial use between two groups were all significant(t= 1.021, 1377.45,both P<0.05).Conclusion Laminar flow ward can reduce the incidence of HAI in patients with initial occurrence of acute leukemia,and decrease cost of antimicrobial use.

3.
Chinese Journal of Infection Control ; (4): 541-543,547, 2014.
Article in Chinese | WPRIM | ID: wpr-599560

ABSTRACT

Objective To compare the bacteriostasis effect of two disinfectants on frequently touched object sur-faces in laminar flow general intensive care unit (GICU),and investigate bacterial contamination on the object sur-faces,so as to provide reference for proper disinfection method and control of infection.Methods Specimens from surfaces of bed rails and bedside tables were taken for bacterial culture before being disinfected.Then object sur-faces around bed units were disinfected with disinfectant containing 500 mg/L of available chloride (routing group) and GammaTM disinfecting wet wipes (control group)respectively,bacteriostasis rate and qualified rate of bacterial count on object surfaces between two kinds of disinfection methods were compared.Results Before routine disinfec-tion,a total of 87 pathogens were isolated from 200 specimens of object surfaces,bacterial contamination rate was 43.50%. Detection rate of gram-positive bacteria was 78.16%% (n =68),the major were Corynebacterium (26.47%,n = 18), Staphylococcus aureus (23.53%,n=16)and Staphylococcus epidermidis (23.53%,n=16);detection rate of gram-nega-tive bacteria was 21.84%(n=19),the major was Acinetobacter baumannii (63.16%,n=12).After a 10-minute disinfec-tion on surfaces,bacteriostasis rate of routine group and control group was (94.89±7.72)% and(96.33 ±12.88)% re-spectively,there was no significant difference between two groups(P >0.05);qualified rates of bacterial count of object surfaces of two groups were both 100%.Conclusion Regular disinfection of object surfaces around bed units,stand-ardization of the manipulation and hand hygiene compliance of medical personnels are simple and effective method of cutting off bacteria dissemination and preventing healthcare-associated infection.

4.
Chinese Journal of Practical Nursing ; (36): 76-77, 2012.
Article in Chinese | WPRIM | ID: wpr-418966

ABSTRACT

Objective To understand the current status of nosocomial infection after renal trans plantation. Methods106 patients after renal transplantation were randomly divided into the laminar flow ward group (54 cases)and the ICU group (52 cases).The nosocomial infection situation of the twogroups was compared.ResultsThe rate of nosocomial infection in the laminar flow ward group was lower than that in the ICU group.The number of bacterial colony in laminar flow wards was less than that in ICU.Conclusions The rate of nosocomial infection in the laminar flow ward was lower than that in the ICU after renal tranaplantation.Patients after renal transplantation should he admitted in laminar flow ward in order to reduce the rate of nosocomial infection.